MATERIAL
Pipes & fitings PVC-C
APPLICATION
- cold and hot water installations
- air conditioning installations
- industrial installations for various chemical compounds
TECHNICAL CHARACTERISTICS
- maximum temperature 80ºC (failure temperature at 95ºC)
- varying (fluctuating) pressure
| PIPE TYPES AND PARAMETERS | ||||||
| Type | Size (inches) | Max. operating pressure kPa(23ºC) | Max. wall thickness (mm) | Internal diameter (mm) | Outer diameter (mm) | Weight (kg/mb) |
| CTS (SDR 11) |
1/2 | 2760 | 1,73 | 12,20 | 15,68 | 0,131 |
| CTS (SDR 11) |
3/4 | 2760 | 2,03 | 17,90 | 22,22 | 0,209 |
| CTS (SDR 11) |
1 | 2760 | 2,59 | 22,60 | 28,56 | 0,325 |
| CTS (SDR 11) |
1 1/4 | 2760 | 3,18 | 27,90 | 34,91 | 0,490 |
| CTS (SDR 11) |
1 1/2 | 2760 | 3,76 | 33,10 | 41,26 | 0,685 |
| CTS (SDR 11) |
2 | 2760 | 4,70 | 43,20 | 53,96 | 1,180 |
| SCH 80 | 2 1/2 | 2900 | 7,00 | 58,16 | 73,00 | 2,173 |
| SCH 80 | 3 | 2550 | 7,62 | 72,74 | 88,90 | 2,917 |
| SCH 80 | 4 | 2210 | 8,56 | 96,16 | 114,30 | 4,643 |